Portable Natural Gas Odorizer Rental and Field Service

Oct 5, 2024
4 min read

Updated: Sep 1

Portable odorization projects can range from an equipment-only rental to a staffed field-service assignment that includes mobilization, operating support, monitoring, verification records and turnover.


Burgess Pipeline Services supports qualifying temporary odorization, pipeline conditioning, commissioning, maintenance-outage and temporary-gas-supply work. The approved proposal should define the equipment, responsibilities, schedule, operating limits, staffing and deliverables for the specific project.


The responsible operator retains authority for regulatory applicability, operating procedures, system limits, emergency decisions and acceptance criteria. BPS provides operational support and documentation, not legal advice.

Choose the Appropriate Rental Model


Equipment-Only Rental


An equipment-only scope may provide a configured portable odorization unit and the accessories and documentation listed in the proposal.


Unless expressly included, the customer or responsible operator remains responsible for:

  • Site engineering and readiness

  • Installation and connection

  • Odorant procurement, storage and handling

  • Startup and shutdown authorization

  • Equipment operation

  • Continuous or periodic monitoring

  • Alarm response

  • Downstream verification

  • Emergency response

  • Demobilization and final acceptance


Equipment-only rental should not be interpreted as including field staffing or operational responsibility unless those services appear in the approved scope.

Turnkey Field Service


A defined field-service scope may include:

  • Mobilization and placement coordination

  • Connection and readiness verification

  • Startup support

  • Scheduled or continuous operating coverage

  • Odorant inventory and refill records

  • Alarm and interruption documentation

  • Operator-authorized adjustments

  • Downstream measurement support

  • Troubleshooting

  • Demobilization

  • Turnover records


The proposal should state operating hours, response expectations, included personnel, exclusions and decision authority.

Hybrid Support


A hybrid scope divides responsibilities among the operator, BPS and other contractors. The responsibility matrix should identify who supplies, connects, operates, monitors, verifies, responds and approves each phase of the work.

When Portable Odorization May Be Useful


A portable system may support:

  • Permanent-odorizer maintenance or replacement

  • Temporary bypass during an outage

  • New-pipeline commissioning

  • Pipeline pickling and conditioning

  • Odor-fade remediation

  • Temporary CNG, RNG or vaporized-LNG supply

  • Gas-source or gate changes

  • Private-campus or industrial gas systems

  • Construction-phase operation

  • A temporary bridge to permanent equipment


Applicability and equipment suitability depend on the actual project conditions.

Information Needed Before Quoting


Provide the available:

  • Project objective and location

  • Requested mobilization and operating dates

  • Expected duration

  • Minimum, normal and maximum gas flow

  • Intermittent-flow and zero-flow conditions

  • Flow measurement basis and signal

  • Minimum, normal and maximum pressure

  • Odorant or blend

  • Operator-selected injection basis

  • Current odorant safety data sheet

  • Injection connection

  • Isolation and depressurization arrangement

  • Downstream sampling locations

  • System branches, loops, gates and alternate sources

  • Electrical power and communications

  • Area classification

  • Site access and equipment-placement restrictions

  • Odorant storage and refill requirements

  • Required alarms and notification recipients

  • Requested staffing and monitoring coverage

  • Verification and turnover requirements


Unknown information should remain marked as unknown until confirmed.


Review Portable Natural Gas Odorizer Project Requirements and Deployment Planning for a more detailed project-data checklist.

Confirm the Equipment and Connection Boundary


The proposal should identify the exact portable system, tank, controls, hoses, regulators, fittings, sample connections, communications and other accessories included in the rental.


BPS has identified a public operating range of 0–70 MMSCF/H at an injection basis of 0.5 lb/MMSCF for qualifying applications. That range does not independently establish suitability for a particular project. Pressure, turndown, flow signal, connections, odorant, utilities, operating mode, area classification and required verification must also be evaluated.


Every component exposed to pressure or odorant service should be confirmed for the intended conditions. A system-level description should not be treated as verification of every hose, fitting or accessory.

Define Monitoring and Response


Before operation, establish:

  • Data to be recorded

  • Monitoring frequency

  • Alarm recipients

  • Notification and escalation path

  • Authority to adjust settings

  • After-hours coverage

  • Odorant refill responsibility

  • Shutdown authority

  • Response to loss of flow signal, power or communications

  • Response to suspected loss of injection

  • Required documentation after an interruption


A displayed injection command does not independently prove that odorant physically entered the gas stream. Available delivery evidence, odorant inventory and representative downstream observations provide different forms of evidence.

Plan Verification and Turnover


Verification records may need to distinguish:

  1. Gas flow, pressure and operating configuration

  2. Commanded odorant injection

  3. Available evidence of actual delivery

  4. Starting inventory, additions and ending inventory

  5. Downstream odorant concentration

  6. Gas-in-air odor intensity

  7. Sampling locations and operating conditions

  8. Alarms, interruptions and adjustments

  9. Operator-approved acceptance criteria

  10. Open limitations and remaining monitoring assignments


Odorant concentration and perceived odor intensity answer different questions. Neither should be substituted for the other.


Rental termination should be connected to operator-approved exit and handoff criteria, not merely the scheduled end of the rental period. Closeout should identify what was observed, which operating configurations were evaluated and what remains unresolved.

Cost and Schedule Drivers


Rental cost and duration may be affected by:

  • Mobilization distance and freight

  • Rental period

  • Equipment and accessory requirements

  • Field staffing and coverage hours

  • Connection fabrication

  • Odorant supply and refill logistics

  • Travel and lodging

  • Monitoring and measurement frequency

  • Standby or backup equipment

  • Site delays

  • Schedule extensions

  • Remobilization

  • Documentation and turnover requirements


A useful estimate should state these assumptions instead of relying only on an equipment day rate.

Request Portable Odorizer Rental Support


For scope review, provide:

  • Project location and requested dates

  • Operating objective

  • Gas-flow and pressure ranges

  • Odorant and injection basis

  • Connections and available utilities

  • Area classification

  • Requested rental model

  • Staffing and monitoring requirements

  • Verification locations

  • Required records and turnover format



BPS provides operational support and documentation, not legal advice.

Frequently Asked Questions


Does BPS offer both equipment-only and turnkey rental?


Both models may be available for qualifying projects. The approved proposal must identify the equipment, staffing, responsibilities and deliverables included.

What determines whether a portable odorizer is suitable?


Suitability depends on the complete operating envelope, not maximum flow alone. Pressure, turndown, zero-flow conditions, signal, connections, odorant, utilities, area classification and verification requirements also matter.

Does rental automatically include odorant and field staffing?


No. Odorant supply, transportation, staffing and monitoring are included only when stated in the approved scope.

What closes a portable-odorization assignment?


Closeout should follow operator-approved exit and handoff criteria supported by the agreed operating, inventory, measurement and turnover records.

 
 